RTP Series

Series Category: Aluminum Electrolytic Capacitors

Series Type: Snap-In

Series Applications: For Laminated Electrical Devices

Series Capacitance Range: 33 - 10000 µF

Series Voltage Range: 10 - 100 VDC & 160 - 450 160

Series Operating Temperature Range: -40 - 105 ºC & -25 - 105 ºC

Terminal Type: Snap-in

Load Life (in hours):

2000

Capacitance Change: Within +/- 20% of the initial measured value.

Dissipation Factor (tanδ): Not more than 200% of the initial specified value

Leakage Current: Not more than initial specified value

Useful Life (in hours): 4000

Capacitance Change: Within +/- 30% of the initial measured value.

Dissipation Factor (tanδ): Not more than 300% of the initial specified value

Leakage Current: Not more than initial specified value

Shelf Life (in hours): 1000

Capacitance Change: Within +/- 20% of the initial measured value.

Dissipation Factor (tanδ): Not more than 200% of the initial specified value

Leakage Current: Not more than initial specified value

Leakage Current Formula: After 5 minutes at +20°C application of rated voltage, leakage current is not more than 0.01CV or 1.5mA, whichever is smaller. C: Nominal Capacitance (uF) V: Rated Voltage (V)

Capacitance Tolerance: +/- 20% at 120 Hz, +20°C

Tan or Dissipation Factor

Measurement Frequency: 120Hz, +20°C

Rated Voltage10162535506080100160 ~ 250 350 ~ 450
Tan (max)0.550.500.450.400.350.300.250.200.150.25

Stability at Low Temperature Table:

Rated Voltage10~100 V160~250 V350~450 V
Z –25°C / +20°C338
Z –40°C / +20°C12--

Frequency Coefficient:

Frequency >
Voltage v
50/60Hz120Hz500Hz1kHz10kHz≥ 50kHz
10~100 V0.901.001.101.151.151.15
160~250 V0.901.001.201.301.451.50
350~450 V0.851.001.201.301.421.45

Temperature Coefficient:

Temperature ºC+40+55+70+85+105
Coefficient2.72.52.11.71.0