RTK Series
Series Category: Aluminum Electrolytic Capacitors
Series Type: Snap-In
Series Capacitance Range: 56 - 2200 µF
Series Voltage Range: 160 - 450 VDC
Series Operating Temperature Range: -40 - 105 ºC
Terminal Type: Snap-in
Load Life (in hours):
3000 |
Capacitance Change: Within +/- 20% of the initial measured value.
Dissipation Factor (tanδ): Not more than 200% of the initial specified value
Leakage Current: Not more than initial specified value
Useful Life (in hours): 5000
Capacitance Change: Within +/- 30% of the initial measured value.
Dissipation Factor (tanδ): Not more than 300% of the initial specified value
Leakage Current: Not more than initial specified value
Shelf Life (in hours): 1000
Capacitance Change: Within +/- 20% of the initial measured value.
Dissipation Factor (tanδ): Not more than 200% of the initial specified value
Leakage Current: Not more than initial specified value
Leakage Current Formula: After 5 minutes at +20°C application of rated voltage, leakage current is not more than 0.01CV or 1.5mA, whichever is smaller. C: Nominal Capacitance (uF) V: Rated Voltage (V)
Capacitance Tolerance: +/- 20% at 120 Hz, +20°C
Tan or Dissipation Factor
Measurement Frequency: 120Hz, +20°C
Rated Voltage | 160 | 200 | 250 | 350 | 400 | 450 |
Tan (max) | 0.15 | 0.15 | 0.15 | 0.15 | 0.12 | 0.12 |
Stability at Low Temperature Table:
Rated Voltage | 160 | 200 | 250 | 350 | 400 | 450 |
Z –40°C / +20°C | 4 | 4 | 4 | 4 | 4 | 4 |
Frequency Coefficient:
Frequency | 50/60Hz | 120Hz | 300Hz | 1kHz | 10kHz | ≥ 50kHz |
Coefficient | 0.8 | 1 | 1.16 | 1.3 | 1.41 | 1.45 |
Temperature Coefficient:
Temperature ºC | +40 | +55 | +70 | +85 | +105 |
Coefficient | 2.7 | 2.50 | 2.10 | 1.70 | 1.00 |
Browse parts in this series
Part numbers are listed and sorted by voltage, then capacitance, then case size
Showing 73–81 of 141 results